[Mon Nov 25 21:22:38 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (start) [Mon Nov 25 21:22:42 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (done) [Mon Nov 25 21:22:47 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh status (start) [Mon Nov 25 21:22:50 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh status (done) [Mon Nov 25 21:22:50 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (start) [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.7: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.6: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.5: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.4: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.3: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.2: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.1: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:00:04.0: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.7: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.6: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.5: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.4: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.3: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.2: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.1: Removing dma and dca services [Mon Nov 25 21:22:53 2024] ioatdma 0000:80:04.0: Removing dma and dca services [Mon Nov 25 21:22:58 2024] nvme nvme0: Device not ready; aborting shutdown, CSTS=0x5 [Mon Nov 25 21:22:58 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (done) [Mon Nov 25 21:22:59 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (start) [Mon Nov 25 21:23:02 2024] nvme nvme0: pci function 0000:5e:00.0 [Mon Nov 25 21:23:02 2024] nvme nvme0: 72/0/0 default/read/poll queues [Mon Nov 25 21:23:02 2024] nvme nvme0: Ignoring bogus Namespace Identifiers [Mon Nov 25 21:23:04 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (done) [Mon Nov 25 21:23:04 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (start) [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.7: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.6: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.5: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.4: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.3: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.2: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.1: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:00:04.0: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.7: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.6: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.5: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.4: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.3: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.2: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.1: Removing dma and dca services [Mon Nov 25 21:23:07 2024] ioatdma 0000:80:04.0: Removing dma and dca services [Mon Nov 25 21:23:12 2024] nvme nvme0: Device not ready; aborting shutdown, CSTS=0x5 [Mon Nov 25 21:23:12 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (done) [Mon Nov 25 21:25:02 2024] nbd0: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:02 2024] nbd1: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:02 2024] block nbd1: Other side returned error (5) [Mon Nov 25 21:25:02 2024] I/O error, dev nbd1, sector 0 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0 [Mon Nov 25 21:25:02 2024] Buffer I/O error on dev nbd1, logical block 0, async page read [Mon Nov 25 21:25:03 2024] block nbd0: NBD_DISCONNECT [Mon Nov 25 21:25:03 2024] block nbd0: Disconnected due to user request. [Mon Nov 25 21:25:03 2024] block nbd1: NBD_DISCONNECT [Mon Nov 25 21:25:03 2024] block nbd1: Disconnected due to user request. [Mon Nov 25 21:25:08 2024] nbd0: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:08 2024] block nbd0: Other side returned error (5) [Mon Nov 25 21:25:08 2024] I/O error, dev nbd0, sector 0 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0 [Mon Nov 25 21:25:08 2024] Buffer I/O error on dev nbd0, logical block 0, async page read [Mon Nov 25 21:25:09 2024] nbd1: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:09 2024] block nbd1: Other side returned error (5) [Mon Nov 25 21:25:09 2024] I/O error, dev nbd1, sector 0 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0 [Mon Nov 25 21:25:09 2024] Buffer I/O error on dev nbd1, logical block 0, async page read [Mon Nov 25 21:25:09 2024] block nbd0: NBD_DISCONNECT [Mon Nov 25 21:25:09 2024] block nbd0: Disconnected due to user request. [Mon Nov 25 21:25:10 2024] block nbd1: NBD_DISCONNECT [Mon Nov 25 21:25:10 2024] block nbd1: Disconnected due to user request. [Mon Nov 25 21:25:15 2024] nbd0: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:15 2024] block nbd0: Other side returned error (5) [Mon Nov 25 21:25:15 2024] I/O error, dev nbd0, sector 0 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0 [Mon Nov 25 21:25:15 2024] Buffer I/O error on dev nbd0, logical block 0, async page read [Mon Nov 25 21:25:15 2024] nbd1: detected capacity change from 0 to 131072 [Mon Nov 25 21:25:15 2024] block nbd1: Other side returned error (5) [Mon Nov 25 21:25:15 2024] I/O error, dev nbd1, sector 0 op 0x0:(READ) flags 0x0 phys_seg 1 prio class 0 [Mon Nov 25 21:25:15 2024] Buffer I/O error on dev nbd1, logical block 0, async page read [Mon Nov 25 21:25:16 2024] block nbd0: NBD_DISCONNECT [Mon Nov 25 21:25:16 2024] block nbd0: Disconnected due to user request. [Mon Nov 25 21:25:16 2024] block nbd1: NBD_DISCONNECT [Mon Nov 25 21:25:16 2024] block nbd1: Disconnected due to user request. [Mon Nov 25 21:29:10 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (start) [Mon Nov 25 21:29:13 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh (done) [Mon Nov 25 21:36:33 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (start) [Mon Nov 25 21:36:36 2024] nvme nvme0: pci function 0000:5e:00.0 [Mon Nov 25 21:36:36 2024] nvme nvme0: 72/0/0 default/read/poll queues [Mon Nov 25 21:36:36 2024] nvme nvme0: Ignoring bogus Namespace Identifiers [Mon Nov 25 21:36:37 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh reset (done) [Mon Nov 25 21:36:37 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh cleanup (start) [Mon Nov 25 21:36:40 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh cleanup (done) [Tue Nov 26 07:16:56 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh status (start) [Tue Nov 26 07:16:58 2024] spdk: /var/jenkins/workspace/BlobFS-phy-autotest/spdk/scripts/setup.sh status (done)